AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |
Back to Blog
Arc flash boundary3/4/2023 Refer to NFPA 70E for additional information. This document will summarize key provisions of NFPA 70E as they apply to work conducted by SUNY NP FOC employees. This guidance is derived from the National Fire Protection Association's (NFPA) recommended standard NFPA 70E, Standard for Electrical Safety in the Workplace. With sufficient energy, an arc flash may become an arc blast producing a dangerous shock wave. The magnitude of the energy and other factors will determine the severity of the arc flash. Occurring in a fraction of a second, it produces a brilliant flash, intense heat, and a shock wave. The arc flash creates electrically conductive superheated plasma that can reach temperatures of 5000° F and above. An arc flash may also occur during movement of energized electrical contactors, such as switches. ![]() ![]() PPE is not required when in proximity to electrical equipment in enclosed panels with no exposed connectors, where electrical work is not being performed and where no high voltage switch is being operated.Īn arc flash may occur when electrical current "short circuits," that is, flows from energized wires or equipment to ground, or between energized wires or equipment with different phases or potential. This guidance applies to situations in which staff may be exposed to arc flash from high voltage switches or live unguarded electrical wires, parts or equipment with voltages above 50 Volts. This guidance document provides guidelines on selection of Personal Protective Equipment (PPE) for protection from electric arc flash from equipment for which detailed arc hazard analysis has not been performed.
0 Comments
Read More
Leave a Reply. |